Multicenter visual outcomes comparison of 2 trifocal presbyopia-correcting IOLs: 6-month postoperative results

Ruth Lapid-Gortzak, Uday Bhatt, Juan Gonzalo Sanchez, Mercè Guarro, Wilson Takashi Hida, Chandra Bala, Ricardo Menon Nosé, Francisco Jose Rodriguez Alvira, Aldo Martinez

Producción científica: Contribución a una revistaArtículo de Investigaciónrevisión exhaustiva

32 Citas (Scopus)

Resumen

PURPOSE: To clinically evaluate visual performance of the AcrySof IQ PanOptix TFNT00 and AT LISA tri 839MP intraocular lenses (IOLs) in binocular visual acuity (VA) and to characterize low-contrast visual performance at 6 months postimplantation. SETTING: Multicenter, 15 sites. DESIGN: Prospective, parallel-group, randomized, double-masked, postmarketing clinical study. METHODS: Binocular uncorrected distance (UDVA, 4 m), intermediate (UIVA, 60 cm), and near (UNVA, 40 cm) visual acuities and binocular defocus curves were evaluated under photopic lighting conditions. Photopic and mesopic contrast sensitivities with and without glare were assessed. RESULTS: The study included 182 subjects (62% women; mean age, 66 ± 9.4 years) who were implanted bilaterally with the TFNT00 IOL (n = 93) or 839MP IOL (n = 89), and binocular VA was evaluated 4 to 6 months (120-180 days) postimplantation. The TFNT00 IOL group showed superior visual outcomes compared with the 839MP IOL group in binocular UIVA (P = .001) and UNVA (P = .003) and noninferior outcomes in UDVA (95% CI, -0.023 to 0.041; upper limit <0.1 logarithm of the minimum angle of resolution [logMAR] [margin of noninferiority]). Mean defocus curve from 0.00 to -3.00 diopter (D) ranged from 0.1 to 0.0 logMAR for both IOLs; better mean VA values (logMAR) were observed in the TFNT00 IOL group between -1.50 and -2.50 D compared with those of the 839MP IOL group. Contrast sensitivity values were similar between the 2 groups in all conditions. CONCLUSIONS: The results of this study showed improved visual performance at near and intermediate distances with the TFNT00 IOL compared with that of the 839MP IOL.

Idioma originalInglés estadounidense
Páginas (desde-hasta)1534-1542
Número de páginas9
PublicaciónJournal of Cataract and Refractive Surgery
Volumen46
N.º11
DOI
EstadoPublicada - nov. 1 2020

Áreas temáticas de ASJC Scopus

  • Cirugía
  • Oftalmología
  • Sistema sensorial

Huella

Profundice en los temas de investigación de 'Multicenter visual outcomes comparison of 2 trifocal presbyopia-correcting IOLs: 6-month postoperative results'. En conjunto forman una huella única.

Citar esto