Difference between both eyes in the calculation of the dioptre power of the intraocular lens in a series of 7994 patients

Título traducido de la contribución: Diferencia entre ambos ojos en el cálculo del poder dióptrico del lente intraocular en una serie de 7.994 pacientes

F. Pólit Huerta, A. F. Pólit Hoyos, J. Pólit Hoyos, N. Molano-González

Producción científica: Contribución a una revistaArtículorevisión exhaustiva

1 Cita (Scopus)

Resumen

Purpose: To analyse the distribution of the difference between both eyes in the calculation of the dioptric power of the intraocular lens in a series of 7994 patients and the biometric variables that determine it. Methods: The data of patients between 3 and 99 years old, residents of the city of Guayaquil and neighbouring sites, who received ocular biometry by partial optical coherence interferometry between 2004 and 2020 were reviewed. Ocular biometrics, including axial length (AL), anterior chamber depth (ACD), and the mean corneal dioptre power (CD), were measured by partial coherence interferometry. Refraction without or with cycloplegia was recorded in spherical equivalent (SE). The Haigis formula from the IOL Master instrument was used to calculate the dioptric power of the intraocular lens in both eyes. Results: Data from the bilateral optical biometry of 7994 patients were analysed. The mean and standard deviation of AL, CD, ACD and dioptre power of the IOL were 23.66 ± 1.25, 43.70 ± 1.49, 3.34 ± 0.40 and +20.46 ± 3.84, respectively. 2538 (31.7%) patients had equal dioptre power of the IOL between both eyes. 3243 (40.6%) patients had a 0.50 D difference; 1162 (14.5%), 1.0 D; 425 (5.3%), 1.5 D. 626 patients (7.8%) had a difference in IOL dioptre of 2 D or more, with a maximum of 24 D. The asymmetry of AL between OU was ≥ 0.4 mm in 10.49%, while that of CD reached ≥ 1 D in 1.9%. Conclusions: 92.16% of patients had a difference within 1.5 D between both eyes in the calculation of the dioptre power of the intraocular lens. In case an eye is programmed in which it is impossible to perform a reliable biometry, either due to trauma or due to white or brunescent cataract, the calculation of the intraocular lens could be done taking as a reference the biometry of the contralateral eye.

Título traducido de la contribuciónDiferencia entre ambos ojos en el cálculo del poder dióptrico del lente intraocular en una serie de 7.994 pacientes
Idioma originalInglés estadounidense
Páginas (desde-hasta)124-132
Número de páginas9
PublicaciónArchivos de la Sociedad Espanola de Oftalmologia
Volumen97
N.º3
DOI
EstadoPublicada - mar. 2022
Publicado de forma externa

Áreas temáticas de ASJC Scopus

  • Oftalmología

Huella

Profundice en los temas de investigación de 'Diferencia entre ambos ojos en el cálculo del poder dióptrico del lente intraocular en una serie de 7.994 pacientes'. En conjunto forman una huella única.

Citar esto