Macular and choroidal thicknesses in a healthy Hispanic population evaluated by high-definition spectral-domain optical coherence tomography (SD-OCT)

Diana A. Cortés, Daniela Roca, Pedro Iván Navarro, Francisco J. Rodríguez

Producción científica: Contribución a una revistaArtículorevisión exhaustiva

4 Citas (Scopus)

Resumen

Purpose: To report normal values of macular and choroidal thickness obtained from a healthy Hispanic population using Optovue (Optovue Inc, Freemont CA, USA) spectral domain optical coherence tomography (SD-OCT). Design: Observational, cross-sectional, correlation study. Methods: A total of 290 eyes (145 healthy subjects) were included; 69% of subjects were female. The median age was 39 ± 29 years (IQR), with a range between 18 and 89 years. The study sample was stratified into three age groups: Group 1, 18–40 years (50.3%), Group 2, 41–60 years (30.7%), and Group 3, older than 61 years (19%). Central macular, perifoveal (inner quadrants), and parafoveal (outer quadrants) thicknesses were estimated. In addition, central and peripheral choroidal thicknesses were estimated. Data analysis was performed to calculate the standardized mean difference according to the variance (Student’s t-test) and its differences with Epidat 4.1. Results: Median macular central thickness was 250 ±30 µm (IQR) with Optovue. Median central choroidal thickness was 263 ± 48 µm (IQR). Median central choroidal thickness was greater than mean peripheral thickness. Macular evaluation showed a statistically significant difference in central, perifoveal, and parafoveal thicknesses, with lower values being recorded for the study sample compared with the manufacturer’s data. Conclusions: SD-OCT has become a useful tool to obtain high-resolution images of the macula and choroid. This method allows precise assessment of the retinal and choroidal layers to diagnose and follow up posterior segment diseases. We are reporting normal cut-off values of macular and choroidal thicknesses in healthy Hispanic subjects evaluated with Optovue SD-OCT as new diagnostic normal parameters for research and clinical activities.

Idioma originalInglés estadounidense
Número de artículo66
Número de páginas10
PublicaciónInternational Journal of Retina and Vitreous
Volumen6
N.º1
DOI
EstadoPublicada - dic. 7 2020

Áreas temáticas de ASJC Scopus

  • Oftalmología

Huella

Profundice en los temas de investigación de 'Macular and choroidal thicknesses in a healthy Hispanic population evaluated by high-definition spectral-domain optical coherence tomography (SD-OCT)'. En conjunto forman una huella única.

Citar esto