T1 - Internal jugular access using pocket ultrasound in a simulated model
T2 - comparison between biplane and monoplane visualization techniques
AU - Garzón, Jair Antonio Ruiz
AU - López, Gloria Catalina Zuluaga
AU - Piñeros-Hernandez, Laura B.
AU - Martínez, Yury Forlan Bustos
N1 - Publisher Copyright:
© 2023, World Interactive Network Focused on Critical UltraSound (WINFOCUS), Milano.
PY - 2023/12
Y1 - 2023/12
N2 - Introduction: Ultrasound is the current standard for central venous access due to its advantages in efficiency and safety. In-plane and out-of-plane visualization techniques are commonly used, but there is no clear evidence showing an advantage of one technique over the other. The objective of this study was to compare the success and time required for biplane visualization vs. in-plane and out-of-plane techniques in simulated models. Methodology: Ten emergency medicine specialists participated in 60 simulated events, with randomization of the visualization technique for each event. Each event required intravenous cannulation of a simulated model for jugular venous access, with a maximum of three attempts allowed. The number of attempts required for each event, success of puncture and venous cannulation, frequency of redirection and puncture of the posterior wall, time required to obtain an optimal window, visualize the needle inside the vessel, and passage of the guidewire were recorded. The success ratios and times required for each visualization technique (biplane, in-plane, and out-of-plane) were compared. Results: Cannulation success rate was 100% for all three techniques. Success on the first attempt was 95% for biplane visualization vs. 100% for in-plane and out-of-plane. The median total time for the procedure was higher for biplane visualization (29.9 s) compared to in-plane (25.2 s) and out-of-plane (29 s), but this difference was not statistically significant (p = 0.999). There were no significant differences in cannulation success, needle redirection, or posterior wall puncture frequency between biplane visualization and in-plane and out-of-plane techniques. Conclusions: This study suggests that biplane visualization with the use of pocket ultrasound for internal jugular cannulation in simulated models did not demonstrate significant differences when compared with in-plane and out-of-plane visualization techniques. Further research with larger sample sizes may be needed to confirm these results.
AB - Introduction: Ultrasound is the current standard for central venous access due to its advantages in efficiency and safety. In-plane and out-of-plane visualization techniques are commonly used, but there is no clear evidence showing an advantage of one technique over the other. The objective of this study was to compare the success and time required for biplane visualization vs. in-plane and out-of-plane techniques in simulated models. Methodology: Ten emergency medicine specialists participated in 60 simulated events, with randomization of the visualization technique for each event. Each event required intravenous cannulation of a simulated model for jugular venous access, with a maximum of three attempts allowed. The number of attempts required for each event, success of puncture and venous cannulation, frequency of redirection and puncture of the posterior wall, time required to obtain an optimal window, visualize the needle inside the vessel, and passage of the guidewire were recorded. The success ratios and times required for each visualization technique (biplane, in-plane, and out-of-plane) were compared. Results: Cannulation success rate was 100% for all three techniques. Success on the first attempt was 95% for biplane visualization vs. 100% for in-plane and out-of-plane. The median total time for the procedure was higher for biplane visualization (29.9 s) compared to in-plane (25.2 s) and out-of-plane (29 s), but this difference was not statistically significant (p = 0.999). There were no significant differences in cannulation success, needle redirection, or posterior wall puncture frequency between biplane visualization and in-plane and out-of-plane techniques. Conclusions: This study suggests that biplane visualization with the use of pocket ultrasound for internal jugular cannulation in simulated models did not demonstrate significant differences when compared with in-plane and out-of-plane visualization techniques. Further research with larger sample sizes may be needed to confirm these results.
UR - http://www.scopus.com/inward/record.url?scp=85173680537&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85173680537&partnerID=8YFLogxK
U2 - 10.1186/s13089-023-00335-4
DO - 10.1186/s13089-023-00335-4
M3 - Research Article
C2 - 37815637
AN - SCOPUS:85173680537
SN - 2036-3176
VL - 15
JO - Ultrasound Journal
JF - Ultrasound Journal
IS - 1
M1 - 42
ER -