TY - JOUR
T1 - Frequency of anesthetic overdose with mean alveolar concentration-guided anesthesia at high altitude
AU - Giraldo, Juan
AU - Acosta, Claudia
AU - Giraldo-Grueso, Manuel
N1 - Publisher Copyright:
© 2019 Medical Gas Research Published by Wolters Kluwer - Medknow.
PY - 2018/12
Y1 - 2018/12
N2 - This study reported the frequency of anesthetic overdose measured with the bispectral index in a high altitude city (Bogotá-Colombia, 2600 meters above sea level). We assembled a prospective cohort of patients. Preoperative variables were described, and 10 minutes after the surgical incision, bispectral index, mean alveolar concentration, mean arterial pressure, and oxygen saturation were recorded. Bispectral index was classified as superficial (60), adequate (40-60), and deep (> 40). Mean alveolar concentration was classified as low (< 0.8), normal (0.8-1.2), and high (> 1.2). We included 50 patients. The mean age of the patients was 36.3 ± 13.5 years; 48% were male and 78% were categorized as ASA I. Mean values of mean alveolar concentration and bispectral index were 1.14 ± 0.18 and 38.66 ± 6.9, respectively. Frequency of anesthetic overdose measured with bispectral index was 54% and only 20% with mean alveolar concentration. In total, 78% of patients received normal mean alveolar concentration values, and among these patients, 49% had deep bispectral index levels and 51% were adequate. There was no correlation between mean alveolar concentration and bispectral index (Pearson r = 0.161, P = 0.246) or between bispectral index and mean arterial pressure (Pearson r = 0.367, P = 0.08). All patients older than 60 years exhibited deep bispectral index levels, and although we did not identify a correlation between age and bispectral index, a tendency was observed (Pearson r = -0.087, P = 0.538). Safe and effective anesthesia overdose could be a common phenomenon. Bispectral index-guided anesthesia could be a helpful and reliable tool in the assessment and prevention of anesthesia overdose at high altitude. The study was approved by the ethics committee of the Fundación Cardioinfantil-Instituto de cardiología, Bogota, Colombia (approved number: 312017).
AB - This study reported the frequency of anesthetic overdose measured with the bispectral index in a high altitude city (Bogotá-Colombia, 2600 meters above sea level). We assembled a prospective cohort of patients. Preoperative variables were described, and 10 minutes after the surgical incision, bispectral index, mean alveolar concentration, mean arterial pressure, and oxygen saturation were recorded. Bispectral index was classified as superficial (60), adequate (40-60), and deep (> 40). Mean alveolar concentration was classified as low (< 0.8), normal (0.8-1.2), and high (> 1.2). We included 50 patients. The mean age of the patients was 36.3 ± 13.5 years; 48% were male and 78% were categorized as ASA I. Mean values of mean alveolar concentration and bispectral index were 1.14 ± 0.18 and 38.66 ± 6.9, respectively. Frequency of anesthetic overdose measured with bispectral index was 54% and only 20% with mean alveolar concentration. In total, 78% of patients received normal mean alveolar concentration values, and among these patients, 49% had deep bispectral index levels and 51% were adequate. There was no correlation between mean alveolar concentration and bispectral index (Pearson r = 0.161, P = 0.246) or between bispectral index and mean arterial pressure (Pearson r = 0.367, P = 0.08). All patients older than 60 years exhibited deep bispectral index levels, and although we did not identify a correlation between age and bispectral index, a tendency was observed (Pearson r = -0.087, P = 0.538). Safe and effective anesthesia overdose could be a common phenomenon. Bispectral index-guided anesthesia could be a helpful and reliable tool in the assessment and prevention of anesthesia overdose at high altitude. The study was approved by the ethics committee of the Fundación Cardioinfantil-Instituto de cardiología, Bogota, Colombia (approved number: 312017).
UR - http://www.scopus.com/inward/record.url?scp=85059933024&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85059933024&partnerID=8YFLogxK
U2 - 10.4103/2045-9912.248265
DO - 10.4103/2045-9912.248265
M3 - Research Article
AN - SCOPUS:85059933024
SN - 2045-9912
VL - 8
SP - 150
EP - 153
JO - Medical Gas Research
JF - Medical Gas Research
IS - 4
ER -