Biofeedback-emg y su aplicación en un caso de hipertonía espástica

Translated title of the contribution: Biofeedback-Emg and it's application in a case of spastic hypertonia

Research output: Contribution to journalArticlepeer-review

Abstract

The purpose of this report was to evaluate the effectivity of electromiographic biofeedback in the spastic hypertonia in a hemiplegic patient. The external twin muscle was monitorized. The EMG level was used before and offer treatment to assess the spacticity grade and also the modified Ashworth clinical scale was performed; 6 sessions of treatment were administered under the some conditions,- 18 essays were involved in each session, getting to 108 in total. The results show a significative reduction of spastic hypertonia level due to learning by the EMG signal exposition.

Translated title of the contributionBiofeedback-Emg and it's application in a case of spastic hypertonia
Original languageSpanish
Pages (from-to)219-228
Number of pages6
JournalClínica y Salud
Volume5
Issue number2
StatePublished - 1994

Fingerprint

Dive into the research topics of 'Biofeedback-Emg and it's application in a case of spastic hypertonia'. Together they form a unique fingerprint.

Cite this